Part Number Hot Search : 
2SC51 BFW13 BA3834 KTC4080 MIG50J7 IRFI4321 HM62V1 WSA520
Product Description
Full Text Search
 

To Download A1500RW Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 15w output power ? 2:1 input voltage range ? compact dip case ? 1,600 vdc i/o isolation ? meets en 55022 ?a? ? single & dual outputs ? 37.5 w/in 3 power density ? industry standard pin-out A1500RW 2:1 input range, 15w single & dual output dc/dc con vert ers series www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com electrical speci? cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. input parameter conditions min. typ. max. units input voltage range 12 vdc input 9.0 12.0 18.0 vdc 24 vdc input 18.0 24.0 36.0 48 vdc input 36.0 48.0 75.0 input filter  (pi) filter (meets en 55022 class ?a?) input re? ected ripple current 20.0 ma p - p output parameter conditions min. typ. max. units output voltage accuracy 1.0 % line regulation, v in = min to max single output 0.2 % dual output 0.5 load regulation, i out = 0% to 100% single output 0.5 % dual output 1.0 cross regulation, dual output see note 1 5.0 % ripple & noise (20 mhz) see note 2 60 mv p - p output power protection 150 % i out transient recovery time, see note 3 25% load step change 250 sec transient response deviation 3.0 % temperature coef? cient 0.02 %/oc output short circuit protection continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage (input/output) 3 seconds 1,600 vdc isolation voltage (case/input, output) 3 seconds 1,600 isolation resistance 500 vdc 1,000 m isolation capacitance 100 khz/1v 2,000 pf switching frequency 250 330 khz emi characteristics parameter standard level radiated emissions en 55022 class a conducted emissions en 55022 class a esd en 61000-4-2 criteria b rs en 61000-4-3 criteria a eft, see note 4 en 61000-4-4 criteria b surge, see note 4 en 61000-4-5 criteria b cs en 61000-4-6 criteria a pfmf en 61000-4-8 criteria a environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +85 oc operating temperature range case +105 oc storage temperature range -40 +125 oc cooling free air convection humidity rh, non-condensing 95 % physical case size 1.25 x 0.80 x 0.40 inches (31.8 x 20.3 x 10.2 mm) case material metal with non-conductive base (ul94v-0) weight 0.705 oz (20g) reliability speci? cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25oc, gnd benign 460 khours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 12 vdc input -0.7 36.0 vdc 24 vdc input -0.7 50.0 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260 oc caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings.
model selection guide mechanical dimensions mechanical notes: all dimensions are typical in inch es (mm) tolerance x.xx = ?.01 (?.25) micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com www.micropowerdirect.com derating curve pin single dual 1 remote on/off remote on/off 2- v in -v in 3- v in -v in 9 no pin common 11 nc -v out 14 +v out +v out 16 -v out common 22 +v in +v in 23 +v in +v in nc: no connection pin connections model number input output over voltage protection (vdc) max capacitive load (f max) ef? ciency (%, typ) fuse rating slow-blow (ma) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load a1501rw 12 9.0 - 18.0 1,309 15 3.3 4,000 0.0 3.9 4,700 86 3,000 a1502rw 12 9.0 - 18.0 1,465 15 5.1 3,000 0.0 6.2 3,300 89 3,000 a1503rw 12 9.0 - 18.0 1,436 15 12.0 1,250 0.0 15.0 600 89 3,000 a1504rw 12 9.0 - 18.0 1,420 15 15.0 1,000 0.0 18.0 400 90 3,000 a1505rw 12 9.0 - 18.0 1,488 15 5.0 1,500 0.0 6.2 1,500 86 3,000 a1506rw 12 9.0 - 18.0 1,420 15 12.0 625 0.0 15.0 288 90 3,000 a1507rw 12 9.0 - 18.0 1,420 15 15.0 500 0.0 18.0 200 90 3,000 a1511rw 24 18.0 - 36.0 647 10 3.3 4,000 0.0 3.9 4,700 87 1,500 a1512rw 24 18.0 - 36.0 732 10 5.1 3,000 0.0 6.2 3,300 89 1,500 a1513rw 24 18.0 - 36.0 710 10 12.0 1,250 0.0 15.0 600 90 1,500 a1514rw 24 18.0 - 36.0 702 10 15.0 1,000 0.0 18.0 400 91 1,500 a1515rw 24 18.0 - 36.0 744 10 5.0 1,500 0.0 6.2 1,500 86 1,500 a1516rw 24 18.0 - 36.0 710 10 12.0 625 0.0 15.0 288 90 1,500 a1517rw 24 18.0 - 36.0 710 10 15.0 500 0.0 18.0 200 90 1,500 a1521rw 48 36.0 - 75.0 327 5 3.3 4,000 0.0 3.9 4,700 86 1,000 a1522rw 48 36.0 - 75.0 370 5 5.1 3,000 0.0 6.2 3,300 88 1,000 a1523rw 48 36.0 - 75.0 359 5 12.0 1,250 0.0 15.0 600 89 1,000 a1524rw 48 36.0 - 75.0 359 5 15.0 1,000 0.0 18.0 400 89 1,000 a1525rw 48 36.0 - 75.0 372 5 5.0 1,500 0.0 6.2 1,500 86 1,000 a1526rw 48 36.0 - 75.0 359 5 12.0 625 0.0 15.0 288 89 1,000 a1527rw 48 36.0 - 75.0 355 5 15.0 500 0.0 18.0 200 90 1,000 notes: 1. when measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 2. when measuring output ripple, it is recommended that an external 1.0 f ceramic capacitor be placed from the +v out pin to the -v out pin for single output units and from each output to common for dual output units. for noise sensitive applications, the use of 3.3 f capacitors will reduce the output ripple. 3. transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%. 4. to meet the requirements of en 61000-4-4 and en 61000-4-5, an external lter capacitor is required. it is recommended that a 680 f/100v (or two 330 f/100v capacitors con- nected in parallel) be used. 5. operation at no-load will not damage these units. however, they may not meet all speci ca- tions. 6. dual output units may be connected to provide a 10 vdc, 24 vdc or 30 vdc output. to do this, connect the load across the positive (+v out ) and negative (-v out ) outputs and oat the output common. 7. it is recommended that a fuse be used on the input of a power supply for protection. see the table a bove for the correct rating. remote on/off parameter min max units supply on 3.0 12 or open vdc supply off 0.0 1.2 vdc standby input current 5 ma typical control common referenced to neg. input (pin 2,3)


▲Up To Search▲   

 
Price & Availability of A1500RW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X